How to wire the dual power transfer switch?
Release time:
2025-04-24
Source:
In the event of a power outage for any reason, and power cannot be restored within a short period of time, backup power must be activated.
First, when there is a power outage for any reason and power cannot be restored within a short period of time, the backup power must be activated.
Steps: Cut off the circuit breakers of the mains power supply (including the circuit breakers of the control cabinet in the distribution room, and the mains power supply breaker of the dual-power switching box), pull the double-cast anti-backing switch to the side of the self-provided power supply, and keep the self-provided power supply circuit breaker in the dual-power switching box in the disconnected state.
Start the standby power supply (diesel generator set), and when the unit is running normally, close the generator air switch and each circuit breaker in the self-provided power control cabinet in sequence.
Close each standby power circuit breaker in the power switching box one by one to send power to each load.
During the operation of the standby power supply, the operation duty personnel shall not leave the generator set, and adjust the voltage and plant frequency in time according to the change of load, and deal with the abnormality in time.
Second, when the mains power supply is restored, the power conversion should be done in time, the backup power supply should be cut off, and the mains power supply should be restored.
Steps: Disconnect the circuit breakers of the self-provided power supply one by one in order, the order is: the self-provided power circuit breaker of the dual power switching box→ the circuit breaker of the self-provided power distribution cabinet→ the main switch of the generator→ and the double switch will be dialed to the side of the mains power supply.
Shut down according to the diesel engine shutdown steps.
In order, close each circuit breaker one by one from the main switch of the mains power supply to each branch switch, and place the circuit breaker of the dual power switching box from the mains power supply in the closed position.
Third, check whether the indicators of each instrument and indicator are normal, and start the cooling fan in the transformer.
Other dynamics
What is the inverter cabinet The role of the inverter cabinet
The inverter cabinet uses the inverter to drag the control cabinet of the power unit. Because of its good starting performance, speed regulation performance and energy-saving effect, it has become the current promoted power drag mode.
The control cabinet of the distribution box should be cleaned and maintained regularly
When the distribution box generator is working, the engineer personnel should concentrate their thoughts and operate cautiously when operating the distribution board. After the motor unit is started, it should be slowly accelerated manually by using the speed up switch of the power screen.
Common fault maintenance and maintenance precautions for power distribution cabinets
Distribution cabinet common fault maintenance and maintenance precautions The distribution box is also called the distribution cabinet, which is the general name of the motor control center.
How to wire the dual power transfer switch?
In the event of a power outage for any reason, and power cannot be restored within a short period of time, backup power must be activated.
Power system automation structure
Power system automation realizes automatic control, automatic scheduling and automatic management of electric energy production, transmission and management. The power system [1] is a complex and large-scale system with a wide geographical distribution, composed of power plants, substations, transmission and distribution networks, and users.
The reason for the heating up of the high-voltage switchgear when it is energized
After a brief familiarity with the high-voltage switchgear, and let's learn the reasons for the heating up of the high-voltage switchgear when it is energized, I don't know if you will be interested in it? We are dedicated to providing you with the best quality service, let's take a look.